
Before You Begin
First Time Operation
NOTE
The following process is used to flush factory testing fluids out
of your new machine, and is only necessary before the first
time you use the unit.
Remember to send in your warranty card to properly register
your machine.
1.
Verify that the unit’s fuel filter is connected and securely in place on the filter base assembly at the rear of
the cabinet
.
2.
Check the output/return hoses, battery connections, and all external components for damage.
3. Turn the Pressure Adjust regulator on the unit control panel counterclockwise until it is completely
open.
4. Attach the unit to a motor vehicle battery by connecting the red battery clip to the positive (+) battery
terminal and connect the black battery clip to a solid ground point as far from the battery as possible.
5.
Fill the unit’s reservoir with clean gasoline until the Fuel Level Window indicates 1/4 tank.
6. Connect the unit’s output (red) hose and return (black) hose together by using the
#060-1100 and #060-1400 adaptors and securing them with a clamp. Follow the procedures below to
flush fuel through the system:
• Press and hold
the Start button for five minutes. This will thoroughly flush the system with clean
gasoline.
• Release the Start button.
7. Disconnect the output and return lines.
8.
Connect the #060-1100 adaptor to the (red) output hose. To flush the gasoline from the unit’s reservoir
using the following procedure:
• Direct the adaptor on the (red) output hose into an appropriate container.
• Press and hold
the Start button until the unit’s reservoir is empty.
• Release the Start button.
• Dispose of the fuel in an environmentally approved method.
DISTRIBUTED BY: TOTAL FACILITY SOLUTIONS | 1(800) 274-8730 | WWW.LIFTANDAIRCOMPRESSOR.COM
Kommentare zu diesen Handbüchern